Designing a House in a Seismic Zone — What a Design for Almaty, Tashkent, Bishkek and Yerevan Must Include

5 min read ·

Most of Central Asia and Armenia is a high-seismicity zone. Almaty, Tashkent, Bishkek, Yerevan and Ashgabat all stand in areas where the codes require buildings to be designed for strong earthquakes. For a private house this means one thing: a design without seismic calculations is not a saving but a risk to your family.

Let's look at how a "seismic" design differs from an ordinary one and what to check before accepting the work.

Why you can't use an ordinary design

A standard catalogue design, or one made for central Russia, is calculated for snow weight, wind and soil — but not for horizontal shaking. In an earthquake the house sways, and the weakest points — corners, openings, wall-to-slab joints — fail first.

Such a design can be adapted, but that is a structural engineer's job, not "redrawing the stamp". It's often cheaper to order the design from the start from a specialist who knows the local codes.

Which codes apply

Each country applies its own seismic codes. In Kazakhstan these are the SP RK and SN RK for construction in seismic areas, in Uzbekistan — ShNK and KMK, in Kyrgyzstan — SN KR, in Armenia — SNRA, in Turkmenistan — SNT. In every country the design seismicity is taken from the seismic zoning map and refined for the specific site: on weak soils it is higher.

So the first question to ask a specialist is which codes they design to and whether they have done projects in your city. More on the differences in the article on design codes in CIS countries.

What the design must include

1. Design seismicity in the general data

The first sheet of the KR (structural) section must state the seismic intensity, in points, the house is designed for and the soil category assumed. If this information is missing, the engineer either ignored seismic loads or forgot to record them.

2. Soil data

Standard practice is a geotechnical survey: drilling boreholes and laboratory soil testing. On weak or waterlogged soil the seismic effect is amplified, and the foundation is designed differently. Surveys cost money, but skimping on them is the main source of foundation mistakes.

3. Seismic belts

Cast-in-place reinforced concrete belts along the top of the walls at every floor level tie the house into a single box. The design must include belt details with reinforcement, not just a note saying "provide a belt".

4. Limits on openings and piers

The codes limit the width of openings and the minimum width of the wall piers between them. Floor-to-ceiling panoramic windows are possible in a seismic zone, but only with a reinforced frame — and that must be visible in the drawings.

5. Connecting floor slabs to walls

Floor slabs must be securely anchored into the walls and belts. Timber floors need steel ties; precast slabs need grouted joints and anchors.

6. A simple plan shape

The simpler and more symmetrical the house is in plan, the better it performs in an earthquake. A complex plan with projections is divided by seismic joints into simple sections. If the architect proposes an L- or U-shaped house, ask the structural engineer how that part has been resolved.

7. Frame or reinforced masonry

For brick and block houses in high-seismicity zones, the codes limit the number of storeys and require reinforced masonry and vertical cores at corners and next to openings. A cast-in-place or precast reinforced concrete frame with infill is often the more sensible choice.

How much it adds to the price

Seismic calculation is mostly the structural engineer's work. The architectural section itself costs hardly any more, but the KR section is more complex and takes longer. As a guide for a 150 m² house, AR together with structures costs 96 000 – 132 000 ₽ in Kazakhstan, 72 000 – 99 000 ₽ in Uzbekistan, 72 000 – 99 000 ₽ in Kyrgyzstan and 90 000 – 124 000 ₽ in Armenia.

On site, seismic design adds concrete, rebar and labour for the belts. But this is incomparably cheaper than what an earthquake does to a house built without calculations.

Checklist for accepting the design

  • The KR section states the design seismicity and the soil category.
  • There is a reference to the survey or to the assumed soil properties.
  • Seismic belt details with reinforcement are drawn.
  • Openings and piers meet the code limits — ask the engineer whether they checked.
  • The fixing of floor slabs and the roof to the walls is shown.
  • For a complex plan — seismic joints.
  • The codes in the general data are your country's, not a neighbour's.

If anything on this list is missing, raise it before paying for the stage. How to organise acceptance is covered in the article how to accept a design from a designer.

Where to find a structural engineer

Look for structural engineers and architects with seismic-zone experience by country:

Payment on NexLance goes through a secure deal: the money for each section goes to the specialist only after you accept it.

Read also

Interior design · Armenia

How Much an Apartment Interior Design Project Costs in Yerevan in 2026

Prices for an apartment interior design project in Yerevan — from a space plan to a full design with visualizations. A worked example for a 70 m² apartment, timelines and what drives the cost.

3 min · October 25, 2026
Interior design

How Much an Apartment Interior Design Project Costs in 2026 — Prices in Russia and Central Asia

A comparison of apartment interior design prices in Russia, Kazakhstan, Armenia, Uzbekistan, Kyrgyzstan and Turkmenistan. A worked example for 70 m² and what each option includes.

2 min · October 25, 2026
Architectural design · Uzbekistan

How Much a Private House Design Costs in Tashkent

House design prices in Tashkent and Uzbekistan — concept, architectural section, structures and the full design. A worked example for a 150 m² house, with timelines.

2 min · October 25, 2026

The site uses essential cookies to work. Yandex Metrica (visit statistics and recording of actions on pages) is switched on only if you press «Accept all» or allow it in the settings. Details are in the Cookie Policy.